Product Class : Power Cables
Power Cables
 
 
    Electric cable is adopted in transmission and distribution system of electricity.The XLPE cable with alternating-current rated voltage of 0.6/1KV and the cross-link XLPE cable of 35KV and below produced by us not only perform well up to the standards of GB12706,IEC60502 and IEC60840,but also have formed a series,ie.cables of flame-retardant model,refractory model,forts-proof model and water-proof model.

    The technique of oxide-blanket insulation has been successfully applied to the flame-retardant series.Not only have XLPE cable of 0.6/1KV and cross-link XLPE flame-retardant cable reached class A of GB/T12666.5 Test on bunched wires or cable,cross-link flame-retardant XLPE cable with rated voltage of 6/10KV and 8.7/15KV has also reached Class A highly flame-retardant qualification with a margin.On the basis of the cross-link flame-retardant XLPE series,we have developed the low-smoke non-halogen highly flame-retardant oxygen-tight electric cable,the low-smoke non-halogen degree of which conforms to the national standard of GB/T17651.1.2 and GB/T17650.1.2.In general, the cross-link flame-retardant XLPE electric cable produced by us has been in the leading position domestically.

    The refractory-modle cable produced by our factory is the copper-cored cable with the rated voltage of 0.6/1KV,low-smoke non-halogen refractory cable and highly flame-retardant cable,the flame-retardant performance of which is in conformity to GB/T12666.6 Test on fire resisting characteristics of wire or cable,so ,generally the electric cable of refractory series performs well.

     The water-proof cable conforms to the standards of IEC502-2.

Type,description,application

No.
Types
Description
Main application
1

VV VLY
VY VLY

PVC insulated and PVC/PE sheathed power cable
For laying indoor,in tunnels and in ducts,unable to bear external mechanical forces.
VV22 VLV22
VV23 VLV23
PVC insualated and PVC/PE sheathed,steel tape armoured power cable
For laying indoor,in tunnels or direct burying in earth able to bear external mechanical forces.
VV32 VLV32
VV33 VLV33 VV42 VLV42 VV43 VLV43
PVC insulated and PVC/PE sheathed,steed wire armoured power cable
For laying in ground along route with large difference of level,able to bear external mechanical forces
2
YJV YJLV
YJY YJLY
XLPE insulated and PVC/PE sheathed power cable
For laying indoor,in tunnels and in ducts,unable to bear external mechanical forces
YJV22 YJLV22
YJV23 TJLV23
XLPE insulated and PVC/PE sheathed,steel tape armoured power cable
For laying indoors,in tuels or direct burying in earth,able to bear external mechanical forces
YJV32 YJLV32
YJV33 YJLV33 YJV43 YJLV43
XLPE insulated and PVC/PE sheathed steel wire armoured power cable
For laying in ground along route with large difference of level,able to bear external mechanical forces

Type
Number
of cores
Nominal cross-sectional area of conductor (mm2)
Type
Number
of cores
Nominal cross-sectional area of conductor (mm2)
Rated voltage(KV)
Rated voltage (KV)
0.6/1
0.6/1
6/6(6/10)8.7/10(8.7/15)26/35(26/45)
Cu
Al
Cu
Al
Cu
Al
VV VLV
VY VLY
1
1.5~1200
4~1200
YJV YJLV
YJY YJLY
1
1.5~1200
4~1200
25~500
35~6300
2
1.5~300
4~300
2
1.5~300
4~300
...
...
3
1.5~300
4~300
3
1.5~300
4~300
25~400
35~400
4
1.5~300
4~300
4
1.5~300
4~300
...
...
5
1.5~300
4~300
5
1.5~300
4~300
...
...
3+1
1.5~300
4~300
3+1
1.5~300
4~300
...
...
3+2
1.5~300
4~300
3+2
1.5~300
4~300
...
...
4+1
1.5~300
4~300
4+1
1.5~300
4~300
...
...
VV22VLV22
VV23VLV23
1
10~500
16~500
YJV22YJLV22
YJV23YJLV23
1
10~500
16~500
25~500
35~6300
2
2.5~300
4~300
2
2.5~300
4~300
...
...
3
2.5~300
4~300
3
2.5~300
4~300
25~400
35~400
4
2.5~300
4~300
4
2.5~300
4~300
...
...
5
2.5~300
4~300
5
2.5~300
4~300
...
...
3+1
2.5~300
4~300
3+1
2.5~300
4~300
...
...
3+2
2.5~300
4~300
3+2
2.5~300
4~300
...
...
4+1
2.5~300
4~300
4+1
2.5~300
4~300
...
...
VV3 VLV32
VV42VLV42
VV33VLV33
VV43VLV43
1
50~500
50~500
YJV32YJLV32
YJV42YJLV42
YJV33YJLV33
YJV43YJLV43
1
50~500
50~500
25~500
35~6300
2
35~300
50~300
2
35~300
50~300
...
...
3
25~300
35~300
3
25~300
35~300
25~400
35~400
4
25~300
35~300
4
25~300
35~300
...
...
5
25~300
35~300
5
25~300
35~300
...
...
3+1
25~300
35~300
3+1
25~300
35~300
...
...
3+2
25~300
35~300
3+2
25~300
35~300
...
...
4+1
25~300
35~300
4+1
25~300
35~300
...
...

1.The single core armoured cables are used for D.C. system only,As for A.C. system, non-megnetical should be used.
2.Defferent five-core cables of 0.6/1kV round and sector structure can be produced to meet with users'requirement.

1. DC resistance of conductor

Nominal cross-sectional area
(mm2)
Max DC,resistance of conductor at 20℃
Nominal cross-sectional area
(mm2)
Max DC,resistance of conductor at 20℃
Nominal cross-sectional area
(mm2)
Max DC,resistance of conductor at 20℃
Cu
Al
Cu
Al
Cu
Al
1.5
12.1
--
35
0.524
0.868
240
0.0754
0.125
2.5
7.41
12.1
50
0.387
1.641
300
0.0601
0.100
4
4.61
74.1
70
0.268
0.443
400
0.0470
0.0788
6
3.08
4.61
95
0.193
0.320
500

0.0366

0.0605
10
1.83
3.08
120
0.153
0.253
630
0.0283
0.0469
16
1.15
1.91
150
0.124
0.206
800
0.0221
0.0367
25
0.727
1.20
185
0.0991
0.164
1000
0.0176
0.0291

2. Alternating voltage test
The electric cable is to undergo the test voltage of the corresponding industrial frequency in the table below for 5 min without breakdown;the U0 is 6-8.7kV cable test voltage in compliance with IEC 6052 from 2.5 U0 up to 3.5 U0; the cable with the rated voltage of 26/35(26/45)kV in conformity to IEC 60840 is to undergo the industrial frequency of 65 kV/30 min without breakdown.

Rated voltage (KV)
0.6
6
8.7
26
Test voltage (KV)
3.5
21
30.5
65

3. Partial discharge test
The test voltage of local discharge of XLPE insulated cable with the rated volage of 6/6(6/10),8.7/10(8.7/15) and 26/35(26/45)kV is increased from 1.5U0 to 1.73Uo according to the internaltional standards of IEC60502 and IEC60840,and the local discharge capacity is 10pC or less for 26/35kV.

4. The capcity,inductance and reactance of power cable

1) The capacity of PVC insutrical power cables rated voltages up to 0.6/1kV

Nominal cross-sectional area of conductor
(mm2)
Capacitance
(μ F/KM)
Nominal cross-sectional area of conductor
(mm2)
Capacitance
(μ F/KM)
Nominal cross-sectional area of conductor
(mm2)
Capacitance
(μ F/KM)
1.5
0.58
35
1.51
240
2.08
2.5
0.69
50
1.50
300
2.12
4
0.70
70
1.79
400
2.21
6
0.82
95
1.81
500
2.34
10
1.11
120
2.01
630
2.63
16
1.35
150
1.98
800
2.92
25
1.32
185
1.99

2) The reactance of PVC insutrical power cables for rated voltages up to 0.6/1kV
Nominal cross-sectional area of conductor
(mm2)
Type
VV、VLV
VY、VLY
(Sing core)

○ ○
VV、VL、VVY、VLY
VV22、VLV22
VV23 VLV23
(Two cores)
VV、VL、VVY、VLY
VV22、VLV22
VV23、VLV23
(3cores、]4cores)
VV、VL、VVY、VLY
VV22、VLV22
VV23、VLV23
(3+1cores)
VV、VL、VVY、VLY
VV22、VLV22
VV23、VLV23
(3+2cores、4+1cores、5cores)
Reactance(Ω /km)
1.5
0.152
0.108
0.108
--
--
2.5
0.136
0.0996
0.0996
--
--
4
0.13
0.0992
0.0992
0.0992
0.0992
6
0.126
0.0935
0.0935
0.0935
0.0935
10
0.114
0.0889
0.0889
0.0889
0.0889
16
0.106
0.0844
0.0844
0.0844
0.0844
25
0.107
0.0848
0.0848
0.0848
0.0848
35
0.103
0.0822
0.0822
0.0822
0.0822
50
0.0954
0.0796
0.0796
0.0796
0.0802
70
0.0912
0.0766
0.0766
0.0766
0.0773
95
0.0891
0.0764
0.0764
0.0764
0.0770
120
0.0854
0.0741
0.0741
0.0741
0.0746
150
0.0873
0.0743
0.0743
0.0743
0.0748
185
0.0857
0.0742
0.0742
0.0742
0.0747
240
0.0839
--
0.0732
0.0732
0.0735
300
0.0834
--
0.0729
0.0729
0.0732
400
0.0816
--
--
--
--
500

0.0803

--
--
--
--
630
0.0781
--
--
--
--
800
0.0755
--
--
--
--


3) The capacity of 0.6/1kV XLPE insutrical power cable

Nominal cross-sectional area of conductor
(mm2)
Capacitance
(μ F/KM)
Nominal cross-sectional area of conductor
(mm2)
Capacitance
(μ F/KM)
Nominal cross-sectional area of conductor
(mm2)
Capacitance
(μ F/KM)
1.5
0.20
35
0.61
185
0.76
2.5
0.24
50
0.63
240
0.82
4
0.29
70
0.69
300
0.86
6
0.34
95
0.80
400
0.88
10
0.47
120
0.82
500
0.93
16
0.57
150
0.78
630
0.98
25
0.53

4) The reactance of 0.6/1kV XLPE insutrical power cable
Nominal cross-sectional area of conductor
(mm2)
Type
YJV、YJLV
YJY、YJLY
YJLV32YJL33
YJLV33
(Sing core)

○ ○
YJV、YJLV
YJY、YJLY
YJV22、YJLV22
YJV23、YJLV23
YJV32、YJLV32
YJV33、YJLV33
YJV42、YJLV42
YJV43、YJLV43
(Two cores)
YJV、YJLV
YJY、YJLY
YJV22、YJLV22
YJV23、YJLV23
YJV32、YJLV32
YJV33、YJLV33
YJV42、YJLV42
YJV43、YJLV43
(3cores、4cores)
YJV、YJLV
YJY、YJLY
YJV22、YJLV22
YJV23、YJLV23
YJV32、YJLV32
YJV33、YJLV33
YJV42、YJLV42
YJV43、YJLV43
(3+1cores)
YJV、YJLV
YJY、YJLY
YJV22、YJLV22
YJV23、YJLV23
YJV32、YJLV32
YJV33、YJLV33
YJV42、YJLV42
YJV43、YJLV43
(3+2cores、4+1cores、5cores)
Reactance(Ω /km)
1.5
0.122
0.0103
0.0103
--
--
2.5
0.115
0.0957
0.0957
--
--
4
0.109
0.0897
0.0897
0.0897
0.0897
6
0.104
0.0850
0.0850
0.0850
0.0850
10
0.101
0.823
0.823
0.823
0.823
16
0.0978
0.0789
0.0789
0.0789
0.0789
25
0.0990
0.0801
0.0801
0.0801
0.0801
35
0.969
0.0780
0.0780
0.0780
0.0780
50
0.0937
0.0131
0.0131
0.0131
0.0780
70
0.0925
0.0300
0.0300
0.0300
0.0748
95
0.0908
0.0284
0.0284
0.0284
0.0736
120
0.0898
0.0274
0.0274
0.0274
0.0720
150
0.0903
0.0279
0.0279
0.0279
0.0709
185
0.0905
0.0281
0.0281
0.0281
0.0714
240
0.0893
--
0.0269
0.0269
0.0704
300
0.0857
--
0.0263
0.0263
0.0699
400
0.0857
--
--
--
--
500
0.0882
--
--
--
--
630
0.0837
--
--
--
--

5) The reactance of 6/6kV(6/10kV) XLPE insutrical power cable

Nominal cross-sectional area of conductor
(mm2)
Type
YJV、YJLV、 YJY、YJLY
YJV32、YJLV32、 YJV33、YJLV33
YJV42、YJLV42、 YJV43、YJLV43
(Sing core)

○ ○
YJV、YJLV、 YJY、YJLY
YJV32、YJLV32、 YJV33、YJLV33
YJV42、YJLV42、 YJV43、YJLV43
(Three cores)
Reactance (Ω /km)
25
0.132
0.124
35

0.128

0.118
50
0.125
0.112
70
0.119
0.106
95
0.111
0.101
120
0.108
0.0971
150
0.105
0.0939
185
0.101
0.0913
240
0.0984
0.0881
300
0.0949
0.0858
400
0.0940
0.0833
500
0.0915
----
630
0.0894
----


1. Power-cable lay notice
1) When cable installation parallel with heating pipes, the distance between them should keep 3m;When cross, should keep 0.5m.
2) When cable installation in parallel or cross with other pipes, the distance between them should keep 0.5m.
3) When cable lay directly in ground, the depth of 1-35 kv cable should not less than 0.7m.
4) When cable is installed (10kv or less) in paralel,the distance between them should be not less than 0.1m, 10-35 kv should not less than 0.25m; when cross should not be less than 0.5m.
5) The temperature of cable installation shoul not less than 00C. The bend radius: multi>= core=15 (D+d), single-core cable>=20(D+d). (D is rhw our diameter of the cable.d is the outer diameter of the donductor).
6) Cable connection (equal or large than 6kv)
[1] When cable end is installed, it must remove the demiconductor shield layer and should not injure insulation when operation. It should avoid knife trace and broken.When necessary , grind it with sand paper.The end fo shield should regular and cleen the carvon layer thoroughly.
[2] The copper-hand sheathed and the steal tape armor of the plastic cable ends must be grounding well. The short cicuit wire should be also according to the same principle in order to avoid induce EMF arise on the end of steal-band even "electricspark" and sheath burned accident when three-phrase unvalance.The grounding wire should use tinner knit copper wire,when connected with cable copper band, it should use tin weld with electric iron instead of blowtorch to avoid damage the insulation.
[3] Three-phase copper-hand should be connected with grounding wire separately. Attention should be paid that the shielded grounding wire and the steel band armor grounding wire should be outlet separately and insulated each other.The position of the welded grounding wire ahould as low as possible.
7) The basic requirement for cable ends and middle connection: A:Conductor connection wel. B:Insulation reliable, recommend use XL heat contracted silicon-rubber insulation material. C: Seal well. D: Mechanical strength enough and suitable enough and suitable for all kinds of working conditions.
8) Cable ends must be prevented from water and outer erosive materials. Avoid the insulation layers ageing led to broken through because of water.
9) The losding and unloading of the cable must use a crane, flatly transportation or putting is prohibited, for large scale cable manpower.
10) When cable can't be installed in time because some reason , it should be layed on a dry place to avoid Sun shine heavily and water going into cable ends.
Attentions: Wire and cable installation should be carried out by the person who is familiar with the features of the wire and vable or professional technicians, if there is still something still unclear, pleade adk corresponding technical department or technical department of ShangHai PuDa Limited Company.

2. The feature of cable using and installation conditions
1)PVC insulated power cable for the rated voltages up to 0.6/1kv
[1] The permitting temperature of continuous working of cable conductor:<=70 0 C
[2] The highest working temperature of cable in occurrence of short circuit: 1600C (the longest lasting period under 5s).
[3] After laying, the cable is to undergo the direct coltage of 3.5kv/15min without breakdown.
[4] Aerial laying
a. The center distance of the parallel laying of the single-core cable: 185mm 2 and below is twice the length of diameter of the cable; 240mm 2 and upwards is 90mm.
b. Temperature of the circumstance:40 0 C
c. The correction factor of current capacity is different circumstance temperature:

Environmental temp.(℃)
20
25
30
35
40
45
The correction factor
1.12
1.06
1.00
0.94
0.87
0.79


[5] Plow-in laying
a. The center distance is twice the length of the diameter of be cable when the single-core cable is laid without contact.
b. Temperature of the circumstance:25℃ 
c. The thermal resistivity of the soil: 1.0ak.m/w
d. The depth of plow-in 0.7m
e. The correction factor of current capacity is different circumstance temperature:
Environmental temp.(℃)
15
20
25
30
35
The correction factor
1.11
1.05
1.00
0.94
0.88

[5] Plow-in laying
a. The center distance is twice the length of the diameter of be cable when the single-core cable is laid without contact.
b. Temperature of the circumstance:25 0 C
c. The thermal resistivity of the soil: 1.0ak.m/w
d. The depth of plow-in 0.7m
e. The correction factor of current capacity is different circumstance temperature:


2. XLPE insulated power cable for the rated voltages up to 35kv
1) The permitting temperature of continuous working of cable conductor:<=90 0 C
2) The highest working temperature of cable in occurrence of short circuit: 185 0 C (the longest period is under 5s).
3) Aerial laying
a. The center distance of the parallel laying of the single-core cable:185mm 2 and below is twice the length of diamerer of the cable; 240 mm 2 and upwards is 90mm.
b. Temperature of thw circumstance:40 0 C
4) Plow-in laying
a. The center distance is twice the length of the diameter of he cable when the single-core is laid without contact.
b. Temperature of circumstance:25 0 C
c. The thermal resistivity of the soil:1.0ak.m/w
d. The depth of plow-in:0.7m
5) The correction factor of current capacity in different circumstance temperature:
Aerial laying
Plow-in laying
Environmental temp. (℃)
10
15
20
25
30
35
40
45
50
10
15
20
25
30
35
40
45
The correction factor
1.26
1.22
1.18
1.14
1.09
1.04
1.0
0.94
0.89
1.11
1.07
1.04
1.00
0.96
0.92
0.87
0.83

0.6/1kV Structures and allowed current-ratings of PVC insulated power cable
0.6/1kV Structure and weight of single-core PVC/PE insulated PVC sheathed power cable
06/1kV Structure and weight of two-core PVC insulated PVC/PE sheathed power cable
0.6v/1kV Structure and weight of two-core PVC insulated steel tape armored PVC/PE sheathed power cable
0.6/1kV Structrues and weight of 3-core PVC insulated PVC/PE sheathed power cable
0.6/1kV Structrues and weight of 3-core PVC insulated steel tape armored PVC/PE sheathed power cable
0.6/1kV Structrues and weight of (3+1)-core PVC insulated PVC/PE sheathed power cable
0.6/1kV Structrues and weight of (3+1)-core PVC insulated steel tape armored PVC/PE sheathed power cable
0.6/1kV Structrues and weight of 4-core PVC insulated PVC/PE sheathed power cable
0.6/1kV Structrues and weight of 4-core PVC insulated steel tape armored PVC/PE sheathed power cable
0.6/1kV Structrues and weight of (3+2)-core PVC insulated PVC/PE sheathed power cable
0.6/1kV Structrues and weight of (3+2)-core PVC insulated steel tape armored PVC/PE sheathed power cable
0.6/1kV Structrues and weight of (4+1)-core PVC insulated PVC/PE sheathed power cable
0.6/1kV Structrues and weight of (4+1)-core PVC insulated steel tape armored PVC/PE sheathed power cable
0.6/1kV Structrues and weight of 5-core PVC insulated PVC/PE sheathed power cable
0.6/1kV Structrues and weight of 5-core PVC insulated steel tape armored PVC/PE sheathed power cable
0.6/1kV Allowed current-ratings of PVC insulated power cable for rated voltage up to 0.6/1kV
0.6/1kV Structures and allowed current-ratings of XLPE insulated power cable
0.6/1kV Structrues and weight of single-core XLPE insulated PVC/PE sheathed power cable
0.6/1kV Structure and weight of two-core XLPE insulated PVC/PE sheathed power cable
0.6/1kV Structure and weight of 3-core XLPE insulated PVC/PE sheathed power cable
0.6/1kV Structure and weight of (3+1)-core XLPE insulated PVC/PE sheathed power cable
0.6/1kV Structure and weight of 4-core XLPE insulated PVC/PE sheathed power cable
0.6/1kV Structure and weight of (3+2)-core XLPE insulated PVC/PE sheathed power cable
0.6/1kV Structure and weight of (4+1)-core XLPE insulated PVC/PE sheathed power cable
0.6/1kV Structure and weight of 5-core XLPE insulated PVC/PE sheathed power cable
0.6/1kV Structure and weight of two-core XLPE insulated steel tape armored PVC/PE sheathed power cable
0.6/1kV Structure and weight of 3-core XLPE insulated steel tape armored PVC/PE sheathed power cable
0.6/1kV Structure and weight of (3+1)-core XLPE insulated steel tape armored PVC/PE sheathed power cable
0.6/1kV Structure and weight of 4-core XLPE insulated steel tape armored PVC/PE sheathed power cable
0.6/1kV Structure and weight of (3+2)-core XLPE insulated steel tape armored PVC/PE sheathed power cable
0.6/1kV Structure and weight of (4+1)-core XLPE insulated steel tape armored PVC/PE sheathed power cable
0.6/1kV Structure and weight of 5-core XLPE insulated steel tape armored PVC/PE sheathed power cable
0.6/1kV Structure and weight of single-core XLPE insulated thin steel wire armored PVC/PE sheathed power cable
0.6/1kV Structure and weight of two-core XLPE insulated thin steel wire armored PVC/PE sheathed power cable
0.6/1kV Structure and weight of 3-core XLPE insulated thin steel wire armored PVC/PE sheathed power cable
0.6/1kV Structure and weight of (3+1)-core XLPE insulated thin steel wire armored PVC/PE sheathed power cable
0.6/1kV Structure and weight of 4-core XLPE insulated thin steel wire armored PVC/PE sheathed power cable
0.6/1kV Structure and weight of (3+2)-core XLPE insulated thin steel wire armored PVC/PE sheathed power cable
0.6/1kV Structure and weight of (4+1)-core XLPE insulated thin steel wire armored PVC/PE sheathed power cable
0.6/1kV Structure and weight of 5-core XLPE insulated thin steel wire armored PVC/PE sheathed power cable
0.6/1kV Structure and weight of two-core XLPE insulated thick steel wire armored PVC/PE sheathed power cable
0.6/1kV Structure and weight of 3-core XLPE insulated thick steel wire armored PVC/PE sheathed power cable
0.6/1kV Structure and weight of (3+1)-core XLPE insulated thick steel wire armored PVC/PE sheathed power cable
0.6/1kV Structure and weight of 4-core XLPE insulated thick steel wire armored PVC/PE sheathed power cable
0.6/1kV Structure and weight of (3+2)-core XLPE insulated thick steel wire armored PVC/PE sheathed power cable
0.6/1kV Structure and weight of (4+1)-core XLPE insulated thick steel wire armored PVC/PE sheathed power cable
0.6/1kV Structure and weight of 5-core XLPE insulated thick steel wire armored PVC/PE sheathed power cable
Allowed current-ratings of XLPE insulated power cable for rated voltage up to 0.6/1kV
6/6(6/10)kV Structure and allowed current of XLPE insulated power cable
6/6(6/10)kV Single-core XLPE insulated PVC/PE sheathed power cable & steel tape armoured power cable
6/6(6/10)kV 3-core XLPE insulated PVC/PE sheathed power cable & steel tape armoured power cable
6/6(6/10)kV Single-core XLPE insulated PVC/PE sheathed steel wire armoured power cable
6/6(6/10)kV 3-core XLPE insulated PVC/PE sheathed steel wire armoured power cable
6/6(6/10)kV Allowed current-ratings of XLPE insulated power cable
8.7/10(8.7/15)kV Structure and allowed current-ratings of XLPE insulated power cable
8.7/10(8.7/15)kV Single-core XLPE insulated PVC/PE sheathed power cable & steel tape armoured power cable
8.7/10(8.7/15)kV 3-core XLPE insulated PVC/PE sheathed power cable & steel tape armoured power cable
8.7/10(8.7/15)kV Single-core XLPE insulated steel wire armoured PVC/PE sheathed power cable
8.7/10(8.7/15)kV 3-core XLPE insulated steel wire armoured PVC/PE sheathed power cable
8.7/10(8.7/15)kV Allowed current-ratings of XLPE insulated power cable
26/35(26/45)kV Structure and allowed current-ratings of XLPE insulated power cable
26/35(26/45)kV Single-core XLPE insulated PVC/PE sheathed power cable & steel tape armoured power cable
26/35(26/45)kV 3-core XLPE insulated PVC/PE sheathed power cable & steel tape armoured power cable
26/35(26/45) kV Single-core XLPE insulated steel wire armoured PVC/PE sheathed power cable
26/35(26/45)kV 3-core XLPE insulated steel wire armoured PVC/PE seathed power cable
26/35kV Allowed current-ratings of XLPE insulated power cable
The structure the rafractory-model cable and the flame-retardant-model cable
Model No.and name of flame retardant and fireproof electric power & cable
PVC insulated steel tape armoured and PVC sheathed flame retardant power cable
PVC insulated steel tape armoured and PVC sheathed flame retardant power cable
PVC insulated and PVC sheathed fire resistant power cable
XLPE insulated and PVC sheathed fire resistant power cable
 
 